    We hold a significant inventory and are in a position to present a fair market price.
      

    Lantronix UDS1100-IAP

     
     
     


    UDS1100-IAP

    External Device Server

    UDS1100-IAP photo
    • In minutes, securely connect factory floor devices to enterprise systems
    • Access, monitor and control equipment over Ethernet
    • Replace dedicated PCs and/or modem lines with fast and reliable Ethernet networking
    • Supports RS-232, RS-422 and RS-485 communications
    • Includes Modbus TCP, ASCII, RTU and DF1 protocols
    • 15kV serial ESD protection
    • Wide -40 70C operating temperature range
    • Environmentally-friendly RoHS and WEEE-compliant

    Remotely Monitor, Manage and Control Industrial Equipment Over the Net

    The UDS1100-IAP is a rugged and powerful tool which enables users to connect, manage and control just about any piece of industrial equipment from virtually anywhere over Ethernet or the Internet.

    This single-port Device Server is a quick, simple and inexpensive way to bring the advantages of real-time or on-demand information access.

    Standards Based Communications

    Using an open Ethernet architecture as a standard provides the flexibility for equipment to communicate to virtually any type of industrial device.

    When used in conjunction with an OPC server, most Windows based HMI, SCADA and PC-based control applications have full access to information in the industrial equipment networked by the UDS1100-IAP.

    Extending Serial Communications Across the Globe

    Our approach to network-enabling devices is transparent to your attached equipment and software so you won't need to change the way you work. Using a method called serial tunneling, the UDS1100-IAP encapsulates serial data into packets and transports it over Ethernet. Serial tunneling can be done in multiple ways:

    • Using Lantronix supplied Com Port Redirector software, Windows device applications not designed for network communications are re-directed to communicate to devices connected to the UDS1100-IAP.
    • Connecting two UDS1100-IAP Device Servers configured to automatically talk to each other over the network creates virtual serial connections that can extend serial communications across a facility or around the world.

    Built-in Web Server

    The built-in web server enables users to access and configure the UDS1100-IAP from a standard web browser. Web pages enabling the UDS1100-IAP to be customized for unique applications can be built using Lantronix development tools. On-board Flash memory provides room for future system software upgrades and maintenance-free, nonvolatile web page storage.

    Easy to Set Up and Use

    The UDS1100-IAP can be set up locally through its serial port, or remotely using Telnet or a web browser. The included DeviceInstaller Windows-based configuration software simplifies setup and provides an easy way to:

    • Assign IP & other network specific addresses
    • Load custom web pages
    • Enable web-based configuration of the Device Server
    • Ping or query the attached device(s) over the network
    • View specific device data files
    • Upgrade firmware
    • Simplify process of installing industrial protocols

    Complete with an auto MDI/MDIX Ethernet interface, the UDS1100-IAP is a powerful device communication solution that's perfect for your most demanding industrial applications.

    Modem Replacement

    In modem emulation mode, the UDS is used to replace dialup modems. The unit accepts modem AT commands on the serial port. It then establishes a network connection to the end device, leveraging network connections and bandwidth to eliminate dedicated modems and phone lines.

    RoHS-compliant, the UDS1100-IAP meets Directive 2002/95/EC on the restriction of the use of certain hazardous substances in electrical and electronic equipment.

    If you're looking for a transparent, cost-effective, and scalable means to network-enable your industrial automation equipment, look no further than the UDS1100-IAP.

    Part NumberDescription
    UD1100IA2-01UDS1100-IAP Device Server
    100-240 VAC International power supply with regional adapters, includes 500-163 cable and ACDIN1001-01 Din rail mount
    Accessories
    500-163DB25M to DB9F serial cable
    ACDIN1001-01Optional DIN-rail mount
    500-171-RDB25M to RS485 and power input screw terminal adapter (order separately)

    Features & Specifications

    Serial Interface
    InterfaceSoftware-selectable RS232, RS422 or RS485 (2 and 4 wire support)
    Connectors1 DB25F DCE serial port
    Data RatesSoftware-selectable baud rate from 300 to 230 KBaud
    Characters7 or 8 data bits
    Parityodd, even, none
    Stop Bits1 or 2
    Control SignalsCTS/RTS (Hardware)
    Flow ControlXON/XOFF (Software)
    Network Interface
    Interface10Base-T/100Base-TX Ethernet port
    • Software selectable Ethernet speed 10/100/Auto
    • Software selectable Half/Full/Auto duplex
    ConnectorRJ45
    StandardsARP, UDP, TCP, ICMP, Telnet, TFTP, AutoIP, DHCP, HTTP, SNMP TCP, UDP, and Telnet, TFTP
    Indicators (LED)
    • Power (green)
    • 10/100 Mb Link (amber/green)
    • 10/100 Activity (amber/green)
    • Diagnostics (red)
    • Status (green)
    Processor
    CPULantronix DSTNI-EX 48 MHz clock
    Memory256 KB zero wait state SRAM, 2 MB Flash
    Management
    • Lantronix DeviceInstaller GUI, Serial login, SNMP, Telnet login, HTTP
    Power
    • 9-30 VDC or 9-24 VAC on barrel connector (1.5 Watts maximum consumption)
    • 9-30 VDC on DB25F serial interface
    • 3.3 VDC on serial interface
    Environmental
    Operating-40 to 70 C (-40 to 158 F)
    Storage-40 to 85 C (-40 to 185 F)
    Packaging
    MaterialMetal enclosure with integrated wall mounts; optional 35 mm DIN-rail mount available
    Dimensions (LxWxH)9.0 x 6.4 x 2.3 cm (3.5 x 2.5 x 0.9 in)
    Weight0.20 kg (0.45 lb)
    IP Rating30
    Agency Approvals
    • UL, CSA, FCC, CE, TUV, CTick, VCCI
    Shipping Dimensions
    Dimensions (LxWxH)24.2 x 19.1 x 11.5 cm (9.5 x 7.5 x 4.5 in)
    Weight1.5 kg (3.0 lbs)
    Included Software
    • Windows 98/ME/NT/2000/XP-based DeviceInstaller configuration software, Com Port Redirector software and related utilities
    Emissions
    FCC Part 15 Subpart B Class ARadiated Emissions 30MHz 1000MHz
    ICES-003 Issue 4 February 2004 Class ARadiated Emissions 30MHz 1000MHz
    AS/NZS CISPR 22: 2004 Class ARadiated Emissions 30MHz 1000MHz
    EN55022: 1998 + A1: 2000 + A2: 2003 Class ARadiated Emissions 30MHz 1000MHz
    VCCI V-3/2005.04 Class ARadiated Emissions 30MHz 1000MHz
    EN61000-3-2: 2000 Class AHarmonic Current Emissions
    EN61000-3-3: 1995 + A1: 2001Fluctuations and Flicker
    Immunity
    EN55024: 1998+A1: 2001 +A2: 2003
    IEC_61000-4-2: 1995ESD 8kV Air Discharge (Direct), 4kV Contact Discharge (Direct/Indirect)
    IEC_61000-4-3: 1995Radiated Immunity 3.0V/m, 1KHz AM Sine Wave at 80%
    IEC_61000-4-4: 1995EFT/Burst 1.0kV Power Lines, 0.5kV I/O Lines
    IEC_61000-4-5: 1995Surge Immunity 1.0kV Common Mode, 1.0 kV Differential Mode
    IEC_61000-4-6: 1996Conducted Immunity 3.0 Vrms, 80% AM Modulated (1KHz)
    IEC_61000-4-8: 1993Magnetic Field Immunity 50Hz 1.0 Arms/m
    IEC_61000-4-11: 1994Voltage Dips and Interrupts (>95%,0.5 periods), (30%,25 periods), (>95%,250 periods)
    Isolation
    • Designed with protection against transients and ESD for use under harsh environments.
    Serial Port15 kV ESD protection on RS232 and RS422/485 transceivers
    Power InputUp to non-repeated 600 W 10/100 usec pulse protection against transient over voltages
    Ethernet Port1500 VAC isolation shielded with shield connected to chassis ground for signal integrity and ESD protection

    Copyright(c) 2018 Argecy Computer Corporation - All rights reserved